Connected Components Workbench (CCW) is Rockwell Automation's software for Micro800 controllers, and its Standard Edition is a free download. This page shows how CCW contacts, coils, timers and counters map to graded labs you can run in a browser.
Independent practice site. Not Rockwell software, and it cannot open CCW project files. Vendor facts last checked 20 November 2026.
No signup for the first program. All 12 beginner labs are free with no card.
CCW gives you an editor and Rockwell's own simulator. It does not grade your logic. Each lab on this site runs your rungs against a simulated machine and checks what the machine did, which is how you find out whether a start/stop circuit or a timer really works.
A short screen recording of the simulator this page links to. It shows Allen-Bradley-style rungs being written and run. It is not a recording of CCW.
The simulator has an Allen-Bradley-style dialect and an IEC 61131-3 dialect. Neither is CCW. The CCW column uses the names in Rockwell's Micro800 General Instructions manual.
| What you want to do | In CCW (Micro800) | Here, Allen-Bradley style | Here, IEC style |
|---|---|---|---|
| Pass power when a bit is on | Direct Contact | XIC | Normally open contact |
| Pass power when a bit is off | Reverse Contact | XIO | Normally closed contact |
| Turn an output on while the rung is true | Direct Coil | OTE | Coil |
| Latch a bit on, and release it | Set Coil and Reset Coil | OTL and OTU | SET and RESET coils |
| Delay before something turns on | TON function block: inputs IN and PT, outputs Q and ET | TON. Done bit T1.DN, elapsed time T1.ACC | TON: inputs IN and PT, outputs Q and ET |
| Count events up to a target | CTU function block: inputs CU, RESET and PV, outputs Q and CV | CTU, with RES to reset it | CTU: inputs CU, R and PV, outputs Q and CV |
| Name a piece of data | A Variable. Global Variables belong to the controller, Local Variables to one program | A named tag | A named variable |
From Rockwell's CCW guide for Logix Designer users. Useful if a job posting or a course uses the other set of words.
| Connected Components Workbench | Studio 5000 Logix Designer |
|---|---|
| Variable | Tag |
| Global Variable | Controller Tag |
| Build | Verify and Assemble |
| Connect / Disconnect | Go Online / Go Offline |
| Discover | Upload and Go Online |
| Lock | Force |
| Run Mode Change (RMC) | Online Editing |
| User-defined Function Blocks (UDFBs) | Add-On Instructions (AOI) |
| User-defined Functions (UDFs) | Subroutine |
| CCWARC file | ACD file |
Each task is a free beginner lab. The simulator grades the behavior, not the exact rungs, so any correct program passes.
In CCW: one Direct Contact and one Direct Coil on a rung. In the Logix theme they show as XIC and OTE.
Here: close the switch and the light must come on; open it and the light must go off.
Beginner lab 1: Switch turns on Light →In CCW: a Set Coil on the start rung and a Reset Coil on the stop rung, both on the same variable.
Here: a momentary start latches the output and a momentary stop releases it.
Beginner lab 7: Latched Start/Stop (SET/RESET) →In CCW: a TON function block with IN and PT, then a contact on its Q output.
Here: the light must come on only after the switch has been held for 2 seconds. In the IEC dialect the block has the same IN, PT, Q and ET names.
Beginner lab 8: Delayed-on light (TON) →In CCW: a CTU function block with CU, RESET and PV, then a contact on its Q output.
Here: five pulses must turn the lamp on, four must not, and the reset input must clear the count.
Beginner lab 10: Count to five (CTU) →Lab pages are public. Running a lab needs a free account; the first program at /try needs no account at all.
You still need CCW itself, and Rockwell's manuals, for:
A sensible order
The beginner labs are free with no card. Pro is $29 a month and adds the larger scenario library. Cancel anytime and keep access to the end of the period.