PLC Simulator
AutomationDirect CLICK learners

CLICK PLC Programming: Practice the Ladder Logic in Your Browser

CLICK is AutomationDirect's small PLC family, and its programming software is a free download. This page shows how CLICK contacts, coils, timers and counters map to graded labs you can run here, so you can practise the logic before you have a CLICK on your desk.

Independent practice site. Not AutomationDirect software, and it cannot open CLICK project files. Vendor facts last checked 20 November 2026.

No signup for the first program. All 12 beginner labs are free with no card.

What the CLICK PLC and its software are

  • The hardware: AutomationDirect's CLICK family includes the original CLICK series and the CLICK PLUS models. The Basic and Standard units have 8 built-in inputs and 6 built-in outputs, and analog units add analog inputs and outputs.
  • The software: the CLICK Programming Software (part number C0-PGMSW) is a free download from AutomationDirect. It runs on a Windows PC and you build programs in ladder logic by dragging instructions onto rungs.
  • The instructions: contacts, an edge contact, a compare contact, Out, Set and Reset coils, Timer, Counter, Math, Copy, Drum, Shift Register and more. AutomationDirect's instruction list describes each one.
  • The download: get the installer from AutomationDirect's software downloads page. We do not host it.

The CLICK software is where you write and download a real CLICK program. What it does not do is tell you whether your logic is correct. That is the part this site covers: each lab runs your rungs against a simulated machine and checks what the machine did.

CLICK instructions next to the dialects used here

The simulator does not have a CLICK dialect. You write rungs in an Allen-Bradley-style dialect or an IEC 61131-3 dialect, on named tags instead of X and Y addresses. The logic is the same; the names differ. The CLICK column comes from AutomationDirect's instruction list and hardware manual.

CLICK instruction names compared with the Allen-Bradley-style and IEC dialects in this simulator
What you want to doIn CLICKHere, Allen-Bradley styleHere, IEC style
Pass power when a bit is onContact Normally Open, on an X, Y, C, T, CT or SC bitXICNormally open contact
Pass power when a bit is offContact Normally ClosedXIONormally closed contact
Turn an output on while the rung is trueOut, usually on a Y or C bitOTECoil
Latch a bit on, and release itSet and ResetOTL and OTUSET and RESET coils
Delay before something turns onTimer set as an ON Delay Timer. Status bit T1, current value in TD1, target called the Set PointTON. Done bit T1.DN, elapsed time T1.ACC, preset PRETON. Output Q, elapsed time ET, preset PT
Delay before something turns offTimer set as an OFF Delay TimerTOFTOF
Count events up to a targetCounter set to count up. Completion bit CT1, current value in CTD1, a separate Reset rungCTU, with RES to reset itCTU. Output Q, count CV, preset PV, reset input R
React once to a changeEdge Contact (rising or falling)Rising and falling edge blocksR_TRIG and F_TRIG
Compare two valuesCompare ContactEQU, NEQ, GRT, GEQ, LES, LEQComparison operators
Move and calculate numbersCopy and Math, on DS, DD, DH and DF registersMOV, ADD, SUB, MUL, DIVMOV, ADD, SUB, MUL, DIV

One real difference to remember: CLICK has a single Timer instruction and a single Counter instruction that you configure in a dialog. The dialects here use separate TON, TOF, CTU and CTD blocks.

CLICK address types

CLICK uses fixed memory types, each with a letter symbol. This list is from the CLICK PLC Hardware User Manual, Chapter 2.

CLICK PLC memory types and symbols
SymbolMemory typeWhat it holds
XInput pointDiscrete inputs.
YOutput pointDiscrete outputs.
CControl relayInternal bits for program control. They are not real-world inputs or outputs.
TTimerTimer status bit: on when the current value reaches the preset.
CTCounterCounter status bit: on when the current value reaches the preset.
SCSystem control relayPre-defined bits that show the status of system functions.
DSData register, integerSingle-word integers.
DDData register, integer2Double-word integers.
DHData register, hexSingle-word hexadecimal values.
DFData register, floating point32-bit real numbers.
XD / YDInput and output registersGroups of discrete points as 16-bit words.
TDTimer registerThe matching timer’s accumulated value.
CTDCounter registerThe matching counter’s accumulated value.
SDSystem data registerPre-defined words that show the status of system functions.
TXTTextASCII text data.
  • I/O numbering is decimal. The manual's example: X216 is the 16th input point on the second module from the CPU. The CPU's own points are X001 to X008 and Y001 to Y006 on the 8-in, 6-out units.
  • Nicknames: the software's Address Picker lets you give an address a nickname, so X001 can read as a start button.
  • Here: every input and output is a named tag from the start, such as SWITCH, STOP or LIGHT. You do not practise X and Y numbering on this site.

Five practice tasks that carry over to CLICK

Each task is a free beginner lab. The lab page shows what the machine must do. The simulator grades the behavior, not the exact rungs, so any correct program passes.

  1. 1

    One contact, one output

    In CLICK terms: a Contact Normally Open on an input such as X001 driving an Out on Y001.

    Here: one contact and one coil on named tags. Close the switch and the light must come on; open it and the light must go off.

    Beginner lab 1: Switch turns on Light →
  2. 2

    A stop button with a normally closed contact

    In CLICK terms: a Contact Normally Closed in series with the output.

    Here: the output must stay on until the stop input turns on. This is where most people first get normally open and normally closed backwards.

    Beginner lab 4: Stop button (NC contact) →
  3. 3

    Latch with Set, release with Reset

    In CLICK terms: a Set on one rung and a Reset on another, both on the same bit.

    Here: a momentary start latches the output and a momentary stop releases it, with OTL and OTU or SET and RESET coils.

    Beginner lab 7: Latched Start/Stop (SET/RESET) →
  4. 4

    An on-delay timer

    In CLICK terms: a Timer configured as an ON Delay Timer, then a contact on its T bit.

    Here: the light must come on only after the switch has been held for 2 seconds, and stay off if the switch is released early.

    Beginner lab 8: Delayed-on light (TON) →
  5. 5

    A counter with a reset

    In CLICK terms: a Counter counting up to a Set Point of 5, a contact on its CT bit, and a Reset rung.

    Here: five pulses from the box sensor must turn the lamp on, four must not, and the reset input must clear the count.

    Beginner lab 10: Count to five (CTU) →

Lab pages are public. Running a lab needs a free account; the first program at /try needs no account at all.

What does not transfer

Practising here does not replace time in the CLICK software. You will still need the vendor tools and manual for:

  • Hardware configuration: choosing the CPU and I/O modules, the power budget, and the System Configuration window.
  • CLICK addressing: X, Y, C, DS and the other memory types, and how module position sets the address.
  • Analog modules: wiring, input and output types, and the analog configuration done in the CLICK software.
  • Modbus and other communication: port setup and the Receive and Send instructions.
  • CLICK-only instructions: Drum, Shift Register, Search, and the High Speed Output and Email instructions on CLICK PLUS.
  • Project files and the PLC itself: this site cannot open, save or convert a CLICK project, and it cannot connect to a PLC.

A sensible order

Learn the logic here, then build it in CLICK

  1. Run the first program with no signup, then work through the 12 free beginner labs.
  2. Download the free CLICK software from AutomationDirect and rebuild labs 1, 4, 7, 8 and 10 with X, Y, T and CT addresses.
  3. When you have a CLICK PLC, download the program to it and wire a switch and a lamp.

The beginner labs are free with no card. Pro is $29 a month and adds the larger scenario library. Cancel anytime and keep access to the end of the period.

Questions

CLICK PLC programming: common questions.

Yes. AutomationDirect lists the CLICK Programming Software (part number C0-PGMSW) as a free download, and its manual shows it running on a Windows PC. Get it from AutomationDirect's own software downloads page, not from a third-party site. We checked AutomationDirect's pages on 20 November 2026.

Sources

All checked on 20 November 2026. Written by Paul.

  1. AutomationDirect, CLICK: Free SoftwareThe CLICK Programming Software is a free download for building ladder logic programs; High Speed Output and Email instructions are only available with CLICK PLUS PLCs.
  2. AutomationDirect, CLICK Programming Software instruction listInstruction names and behavior: Contact Normally Open, Contact Normally Closed, Edge Contact, Compare Contact, Out, Set, Reset, Timer, Counter, Math, Copy, Receive and Send.
  3. AutomationDirect, CLICK PLC Hardware User Manual (C0-USER-M, 6th Edition, Rev. Q), Chapter 2: SpecificationsMemory types and symbols (X, Y, C, T, CT, SC, DS, DD, DH, DF, XD, YD, TD, CTD, SD, TXT), the I/O numbering system, analog PLC units and the RS-485 port for Modbus RTU.
  4. AutomationDirect, CLICK PLC Hardware User Manual, Chapter 1: Getting StartedThe programming software (part number C0-PGMSW) runs on a Windows PC and is a free download.
  5. AutomationDirect, CLICK Programming Software specification sheet (C0-PGMSW)Free download; the Address Picker assigns nicknames to memory addresses; subroutine and interrupt programs.
  6. AutomationDirect, CLICK PLC Family OverviewThe family includes the original CLICK series and CLICK PLUS models; Modbus RTU on serial ports and Modbus TCP on Ethernet ports; analog inputs and outputs on analog units.