A belt carries parts to a station. An incremental encoder on the drive roller sends one pulse (ENC_PULSE) for every 10 mm the belt moves, so the PLC can measure distance by counting pulses. It only pulses while the belt is really moving. Tap START and the belt runs. Count the pulses with a counter; when the belt has moved 200 mm it must stop and AT_TARGET must light. Work out how many pulses 200 mm is. STOP pauses the belt without losing the count, so START carries on to the same 200 mm mark. RESET clears the count so the next move can begin.
Objectives
- START runs the belt (BELT_RUN stays on after the button is released)
- The belt keeps running until 200 mm of travel has been counted
- At 200 mm the belt stops and AT_TARGET lights
- STOP pauses the belt without clearing the count
- RESET clears the count so a new move can start
Hints
- A distance is just a number of pulses: how far does the belt move for each pulse, and how many pulses is the whole move?
- A counter adds one to its count for every rising edge on its count input. Its done output turns on when the count reaches the preset, and that is the moment to stop the belt.
- STOP and the counter's done output are two different reasons to stop the belt. Only RESET should clear the count, so a paused move can be resumed.
- If the belt never stops, compare your preset with the number of 10 mm pulses in 200 mm. If it stops at the wrong place, the preset is off by a factor.
I/O Table
Inputs
START_PBStart push-button (momentary NO)
BOOL · %I0.0
STOP_PBStop push-button (TRUE = pressed)
BOOL · %I0.1
RESET_PBCount reset push-button (momentary)
BOOL · %I0.2
ENC_PULSEEncoder: one pulse per 10 mm of belt
BOOL · %I0.3
Outputs
BELT_RUNBelt motor run command
BOOL · %Q0.0
AT_TARGETTarget distance reached lamp
BOOL · %Q0.1
Your program will be tested against:
All test cases run automatically when you submit. Assertions are hidden until you pass.
- #1Tap START → belt runs, target lamp off
A momentary START latches the belt on
- #2After 3.6 s (about 170 mm) → still running
The count has not reached the target yet
- #3After 4.6 s → stopped at 200 mm, target lamp on
Twenty pulses stop the belt and light AT_TARGET
- #4STOP during the move → belt off and stays off
STOP switches the belt off without lighting the target lamp
- #5STOP then START → carries on to the same 200 mm mark
STOP does not clear the count
- #6RESET clears the count → target lamp off, START runs again
RESET reaches the counter and a new move can begin